Aboveground and underground storage tanks
Storage tanks in the chemical process industries (CPI) can be most broadly divided into those buried underground, and those constructed aboveground. The following is an outline of considerations associated with each category and positive and negative aspects of each....
This information is only available to Gold members.
Forgot your user ID or password? Click here to have it sent to you.
Not a member yet?
UPGRADE now to full archive accces and you will receive:
A discount on full delegate pass to ChemInnovations.
Free pass to ChemInnovations show floor.
Discounts on store items and and webinars.
Comments(2) for Aboveground and underground storage tanks
1.
It is articles like this one that cause me a major headache. Our company deals in assisting clients with their regulatory compliance. When I see a client who has an underground tank my first question is why. The answer is we need the above ground space.
There is a third option, overlooked by most and that is to place the tank in a vault. The result is that the tank is regulated as an above ground tank, with all of the advantages of an underground tank. Their next comment is, but no one told me.
Yes, the initial cost is a little more, but the savings over the long run are considerable.
Posted by George on Monday, December 7, 2009 @ 03:01 PM
2.
Mr. G. Moczulski comments on the November 2009 “Facts at Your Fingertips – Aboveground and Underground Storage Tanks” makes the statement that storage tanks in vaults are regulated as aboveground storage tanks. The inference is that only regulations for aboveground storage tanks apply to such installations. This is true only for the tank itself.
For installations that store flammable or combustible liquids, the vault is governed by Chapter 25 of the 2008 edition of NFPA 30, Flammable and Combustible Liquids Code. (Chapters 21 and 22 of this code apply to the tank itself.)
Chapter 25 establishes construction requirements for the vault, including a requirement for anchoring the vault, so that it cannot “float” due to high ground water levels. The chapter also includes requirements for the following: means to admit a fire suppressing agent; possible need for hazardous (classified) electrical utilization equipment and wiring; containment and drainage of spills; ventilation systems; vapor and liquid detection and alarm systems; etc.
While NFPA 30 applies only to flammable and combustible liquids, some of the provisions of Chapter 25 would likely be considered appropriate for storage of liquids with other hazards. Of course, the designer must factor in the cost of all these features, as well as the cost of proper inspection and maintenance.
NFPA 30 is adopted in the laws of 30-plus states.
Robert P. Benedetti, CSP, PE Principal Flammable Liquids Engineer National Fire Protection Association
Posted by Robert P. Benedetti, on Thursday, May 20, 2010 @ 06:50 PM
Join other CPI professionals from all over the globe and share best practices, expertise, concerns and more.
Provide feedback to Chemical Engineering Editors
Current members represent Worley Parsons, DuPont, SABIC, Fluor, Air Products, LyondellBasell, Nalco, Dow Chemical, Dow Corning, BASF, Jacobs Engineering, ExxonMobil, Shell, Chevron and more.
There is a third option, overlooked by most and that is to place the tank in a vault. The result is that the tank is regulated as an above ground tank, with all of the advantages of an underground tank. Their next comment is, but no one told me.
Yes, the initial cost is a little more, but the savings over the long run are considerable.
For installations that store flammable or combustible liquids, the vault is governed by Chapter 25 of the 2008 edition of NFPA 30, Flammable and Combustible Liquids Code. (Chapters 21 and 22 of this code apply to the tank itself.)
Chapter 25 establishes construction requirements for the vault, including a requirement for anchoring the vault, so that it cannot “float” due to high ground water levels. The chapter also includes requirements for the following: means to admit a fire suppressing agent; possible need for hazardous (classified) electrical utilization equipment and wiring; containment and drainage of spills; ventilation systems; vapor and liquid detection and alarm systems; etc.
While NFPA 30 applies only to flammable and combustible liquids, some of the provisions of Chapter 25 would likely be considered appropriate for storage of liquids with other hazards. Of course, the designer must factor in the cost of all these features, as well as the cost of proper inspection and maintenance.
NFPA 30 is adopted in the laws of 30-plus states.
Robert P. Benedetti, CSP, PE
Principal Flammable Liquids Engineer
National Fire Protection Association